380 VAC/28 VDC Multifunctional Fire Control Radar Power Distribution Unit
380 VAC/28 VDC Multifunctional Fire Control Radar Power Distribution Unit
Specially designed for fire control radars. While the designed power distribution unit can be fed from five different sources, it supplies both alternating current and direct current outputs. The power distribution unit is qualified in the relevant military standards for land platforms and is suitable for in-vehicle/shelter use. It can transfer system information and in-circuit test results to the user via its
LCD screen.
Input Voltage Range | AC Input Frequency Range | Number of Switched Outputs | Rated Installed Power |
---|---|---|---|
176–265 VAC 18–36 VDC |
47–63 Hz | 48 |
55 kVA (AC) 2,8 kW (DC) |
TECHNICIAL SPECIFICATIONS
Input Features:
Input Voltage | 400 VAC/50 Hz 3-phase Battery: 28 VDC rated Battery Charging Unit: 28 VDC rated Alternator: 28 VDC rated |
---|---|
Input Voltage Range |
AC Inputs: 176–265 VAC phase-neutral DC Inputs: 18–36 VDC |
AC Input Voltage Frequency Range | 45–55 Hz |
No-load Power Consumption | <3,0 A |
Output Features:
Number of AC Outputs Switched | 29 |
---|---|
Number of DC Outputs Switched | 19 |
AC Input Installed Power | 250 A/3-phase |
AC Input Installed Power | 100 A |
Mechanical Properties:
Width | 850+1 mm |
---|---|
Height | 900+1 mm |
Depth | 700+1 mm |
Weight | 155+5 kg |
Electromagnetic Compatibility:
MIL-STD-461G |
CE102 CS101, CS114, CS115, CS116 RE102 RS103 |
Environmental Characteristics:
Operating Temperature |
MIL-STD-810G -35 C ~ +55 C |
---|---|
Storage Temperature |
MIL-STD-810G -45 C ~ +65 C |
Storage Temperature | MIL-STD-810G A1 Climatic Zone |
Rain | MIL-STD-810G, Method 506.5, Procedure II |
Low Pressure | MIL-STD-810G, Method 500.5, Procedure II |
Mechanical Shock | MIL-STD-810G Method 516.6 Shock, Procedure I Functional Shock, 20 g 11 ms |
Vibration | MIL-STD-810G, Category 20, Military Ground Vehicles |
Humidity | MIL-STD-810G %95 humidity (Without condensation)) |
Dust | MIL-STD-810G Method 510.5 Procedure II |
Output Features:
AC input high voltage protection | Closes the AC outputs. |
---|---|
AC input low voltage protection | Closes the AC outputs. |
DC input high voltage protection | Closes the DC outputs. |
DC input low voltage protection | Closes the DC outputs. |
Unit over-temperature protection | Gives warning. |
Battery reverse connection protection | The DC outputs do not supply from the battery |