115 VAC (400 Hz) Input 28 VDC (1200 W) Output Power Converter Unit
115 VAC (400 Hz) Input 28 VDC (1200 W) Output Power Converter Unit
Power Converter Unit: It converts the 3-phase 115 VAC/400 Hz alternating current it receives from the platform to 28 V direct current and transmits it to the units connected to its output through two separate channels that can be switched independently by providing the necessary protections. The Power Converter Unit can also transfer the AC power supply to the output as two channels in accordance with the discrete input signals. The Power Converter Unit has an output power of 1.2 kilo-watts and has a minimum efficiency of 88%. There is no fan inside the converter, cooling is provided by transmission. Power Converter Unit can also operate with 270 VDC input voltage besides 3 phase AC voltage. In case of power cuts, the unit can deliver 5 amps of 28 VDC output voltage from the first DC output channel for 50 ms. The converter unit can be controlled and commanded externally via the RS-485 interface.
Input Voltage Range | Input Voltage Range | Number of Switched Outputs | Output Voltage | Rated Installed Power |
---|---|---|---|---|
75–160 VAC 180–400 VDA |
393–407 Hz | 4 | 28 VDC | 1,2 kW |
TECHNICIAL SPECIFICATIONS
Input Features:
Input Features |
115 VAC/400 Hz 3-phase 270 VDC |
---|---|
Input Voltage Range |
AC Input: 75–160 VAC phase-neutral DC Input: 180–370 VDC |
AC Input Voltage Frequency Range | 393–407 Hz |
No-load Power Consumption | <0,5 A |
Output Features:
Output Voltage | 28,0+0,5 VDC |
---|---|
Rated Output Power | 1.200 W |
Rated Output Power | +0.5 VDC |
Output Current | 45 A |
Mechanical Properties:
Width | 170+1 mm |
---|---|
Height | 80+1 mm |
Depth | 210+1 mm |
Weight | 2.5+0,1 kg _ |
Electromagnetic Compatibility:
MIL-STD-461G |
CE102 CS101, CS114, CS115, CS116 RE102 RS103 |
Environmental Characteristics:
Operating Temperature | MIL-STD-810G, -40 C ~ +70 C |
---|---|
Storage Temperature | MIL-STD-810G, -40 C ~ +70 C |
Temperature Shock |
MIL-STD-810G, Method 503.5, Procedure I, -40 C ~ +70 C |
Mechanical Shock |
MIL-STD-810G, Method 516.6, Procedure I (Functional, 40 g 11 ms) |
Vibration | MIL-STD-810G, Method 514.8 |
Altitude | MIL-STD-810G, 20.000 ft |
Humidity | MIL-STD-810G, Method 507.6 |
Dust |
MIL-STD-810G, Method 510.5 Procedure I/II |
Protections:
AC input high voltage protection | Closes the DC outputs. |
---|---|
AC input low voltage protection | Gives warning. |
DC input high voltage protection | DC input high voltage protection |
DC input high voltage protection | Gives warning. |
Unit over-temperature protection | Closes the DC outputs. |
Electrical Properties:
MIL-HDBK-704–1 |
TAC101, TAC102, TAC103, TAC104, TAC105, TAC106, TAC107, TAC108, TAC109, TAC110, TAC201, TAC301, TAC302, TAC303, TAC401, TAC601, TAC602, TAC603 |