380 VAC/28 VDC Electro Optical System Power Distribution Unit
380 VAC/28 VDC Electro Optical System Power Distribution Unit
It is specially designed for electro-optical system. While the designed power distribution unit can be fed from two different sources, it supplies both alternating current and direct current outputs. The power distribution unit is qualified in the relevant military standards for land platforms and is suitable for in-vehicle/shelter use. Outputs are switched as solid state. It has the ability to turn off/on the remote outputs with its built-in embedded software. CIT (In-Circuit Test) statuses are displayed to the user through the interface program.
Input Voltage Range | Number of Switched Outputs | Rated Installed Power |
---|---|---|
9–36 VDC | 20 |
2.8 kVA (AC) 7 kW (DC) |
TECHNICIAL SPECIFICATIONS
Input Features:
Input Voltage |
380 VAC/50 Hz 3-phase Battery: 28 VDC rated |
---|---|
Input Voltage Range |
AC Inputs: 176–265 VAC phase-neutral DC Inputs: 9–36 VDC |
AC Input Voltage Frequency Range | 45–55 Hz |
No-load Power Consumption | <2,5 A |
Output Features:
Number of AC Outputs Switched | 3 |
---|---|
Number of DC Outputs Switched | 17 |
AC Input Installed Power | 13 A/1-phase |
DC Input Installed Power | 250 A |
Mechanical Properties:
Width | 340+1 mm |
---|---|
Height | 200+1 mm |
Depth | 350+1 mm |
Weight | 15+0,5 kg |
Electromagnetic Compatibility:
MIL-STD-461F |
CE102 CS101, CS114, CS115, CS116,CS118 RE102 RS103 |
Environmental Characteristics:
Operating Temperature |
MIL-STD-810G -32 C ~ +63 C |
---|---|
Storage Temperature |
MIL-STD-810G -40 C ~ +70 C |
Solar Radiation | MIL-STD-810G, A2 Climatic Zone |
Rain |
MIL-STD-810G, Method 506.5, Procedure I |
Low Pressure |
MIL-STD-810G, Method 500.5, Procedure II |
Mechanical Shock |
MIL-STD-810G Method 516.6 Shock, Procedure I Functional Shock, 20 g 11 ms |
Vibration |
MIL-STD-810G, Category 20, Category 8, Military Ground Vehicles |
Humidity |
MIL-STD-810G, %95 humidity (Without condensation) |
Dust |
MIL-STD-810G, Method 510.5 Procedure I, Tossing Dust |
Protections:
AC input high voltage protection | Closes the AC outputs. |
---|---|
AC input low voltage protection | Closes the AC outputs. |
DC input high voltage protection | Closes the DC outputs. |
DC input low voltage protection | Closes the DC outputs. |
Battery reverse connection protection | The DC outputs do not supply from the battery. |