Ground Vehicle Weapon Control Unit Fire Control Console (AKK), Command Control Console (KKK), FIS Control Unit (FIS KB)
Ground Vehicle Weapon Control Unit Fire Control Console (AKK), Command Control Console (KKK), FIS Control Unit (FIS KB)
Control units are specially designed for the requirements. Control units work with 28 VDC input voltage. In addition to direct 28 VDC outputs, it has one isolated 24 VDC output. It has two RS485 and 10 ethernet interfaces.
TECHNICIAL SPECIFICATIONS
Input Features:
Input Voltage | 28 VDC rated |
---|---|
Input Voltage Range | 18–36 VDC |
No-load Power Consumption | <2,5 A |
Output Features:
Number of DC Outputs Switched | 1 |
---|---|
Number of RS485 | 2 |
Number of Ethernet | 10 (AKK-KKK), 5 (FIS KB) |
Mechanical Properties:
Width | 467+1 mm |
---|---|
Height | 78+1 mm |
Depth | 285+1 mm |
Weight | 7+0,2 kg |
Electromagnetic Compatibility:
MIL-STD-461G |
CE102 CS101, CS114, CS115, CS116 RE102 RS103 |
Environmental Characteristics:
Operating Temperature |
MIL-STD-810G -32 C ~ +50 C |
---|---|
Storage Temperature |
MIL-STD-810G -40 C ~ +63 C |
Solar Radiation |
MIL-STD-810G, Metot 505.5, Procedure I, Category A2 |
Rain |
MIL-STD-810G, Method 506.5, Procedure III MIL-STD-810G, Method 506.5, Procedure I |
Low Pressure | MIL-STD-810G, Method 500.5, Procedure II |
Mechanical Shock |
MIL-STD-810G Method 516.6 Shock, Procedure I Functional Shock, 40 g 11 ms |
Vibration |
MIL-STD-810G, Category 20-a, Procedure II, MIL-STD-810G, Category 20-a, Procedure II, Chart 514–6C-IV, Figure 514.6C-2 AECPT-400 Ed.3, Figure B-4 |
Humidity |
MIL-STD-810G, Method 507.5, Figure 507.5–7, Procedure II %95 humidity (Without condensation) |
Sand and Dust |
MIL-STD-810G, Method 510.5 Procedure I and Procedure II |
Protections:
DC overcurrent | Closes the DC output. |