Power Distribution Unit for Navy Ship Satellite System
Power Distribution Unit for Navy Ship Satellite System
The power distribution unit distributes the power from the 115 VAC/60 Hz source to 10 different outputs. In addition, it feeds one output with a converter that can be adjusted to 9, 12, 16, 20, 24 and 28 VDC output voltage levels. The power distribution unit is 19 rack mountable and has a height of 2 U.
TECHNICIAL SPECIFICATIONS
Input Features:
Input Voltage | 115 VAC/60 Hz 1-phase |
---|---|
Input Voltage Range |
AC Inputs: 103.5–126.5 VAC phase-neutral |
AC Input Voltage Frequency Range | 46–66 Hz |
No-load Power Consumption | <1,0 A |
Output Features:
Number of AC Outputs Switched | 10 |
---|---|
Number of DC Outputs Switched | 1 |
DC Input Installed Power | 25 A |
Mechanical Properties:
Width | 483+1 mm |
---|---|
Height | 88+1 mm |
Depth | 370+1 mm |
Weight | 15+0,5 kg |
Electromagnetic Compatibility:
MIL-STD-461F (Navy, Surface Ships Below Deck) |
CE101, CE102 CS101, CS106, CS114, CS115, CS116 RE101, RE102 RS101, RS103 |
Environmental Characteristics:
Operating Temperature |
MIL-STD-810G w/Change 1 0 C ~ +45 C |
---|---|
Storage Temperature |
MIL-STD-810G w/Change 1 -10 C ~ +60 C |
Sudden Temperature Change |
MIL-STD-810G w/Change 1 Method 503.6 |
Noise | MIL-STD-1472G, it does not produce more than 75 dB of noise |
Mechanical Shock |
MIL-S-901D, Shock Grade: B, Equipment Class: II, Shock Type Test: Type A, Test Category: Medium Weight Shock Test |
Vibration |
MIL-STD-810G w/Change 1, Method 514.7, MIL-STD-810G w/Change 1, Category 21, Method 528.1 |
Humidity | MIL-STD-810G, %95 humidity (Without condensation) |